       The filling of vials that are to be lyophilized has some problems that are somewhat unique. The stopper is placed on top of the vial and is ultimately seated in the lyophilizer. As a result the contents of the vial are subject to contamination until they are actually sealed. 

       Validation of filling operations should include media fills and the sampling of critical surfaces and air during active filling (dynamic conditions).

       Because of the active involvement of people in filling and aseptic manipulations, an environmental program should also include an evaluation of microbiological levels on people working in aseptic processing areas. One method of evaluation of the training of operators working in aseptic processing facilities includes the surface monitoring of gloves and/or gowns on a daily basis. Manufacturers are actively sampling the surfaces of personnel working in aseptic processing areas. A reference which provides for this type of monitoring is the USP XXII discussion of the Interpretation of Sterility Test Results. It states under the heading of "Interpretation of Quality Control Tests" that review consideration should be paid to environmental control data, including...microbial monitoring, records of operators, gowns, gloves, and garbing practices. In those situations in which manufacturers have failed to perform some type of personnel monitoring, or monitoring has shown unacceptable levels of contamination, regulatory situations have resulted.

        Typically, vials to be lyophilized are partially stoppered by machine. However, some filling lines have been noted which utilize an operator to place each stopper on top of the vial by hand. At this time, it would seem that it would be difficult for a manufacturer to justify a hand-stoppering operation, even if sterile forceps areemployed, in any type of operation other than filling a clinical batch or very small number of units. Significant regulatory situations have resulted when some manufacturers have hand-stoppered vials. Again, the concern is the immediate avenue of contamination offered by the operator. It is well recognized that people are the major source of contamination in an aseptic processing filling operation. The longer a person works in an aseptic operation, the more microorganisms will be shed and the greater the probability of contamination.

        Once filled and partially stoppered, vials are transported and loaded into the lyophilizer. The transfer and handling, such as loading of the lyophilizer, should take place under primary barriers, such as the laminar flow hoods under which the vials were filled. Validation of this handling should also include the use media fills. 

        Regarding the filling of sterile media, there are some manufacturers who carry out a partial lyophilization cycle and freeze the media. While this could seem to greater mimic the process, the freezing of media could reduce microbial levels of some contaminants. Since the purpose of the media fill is to evaluate and justify the aseptic capabilities of the process, the people and the system, the possible reduction of microbiological levels after aseptic manipulation by freezing would not be warranted. The purpose of a media fill is not to determine the lethality of freezing and its effect on any microbial contaminants that might be present. 

         In an effort to identify the particular sections of filling and aseptic manipulation that might introduce contamination, several manufacturers have resorted to expanded media fills. That is, they have filled approximately 9000 vials during a media fill and segmented the fill into three stages. One stage has included filling of 3000 vials and stoppering on line; another stage included filling 3000 vials, transportation to the lyophilizer and then stoppering; a third stage included the filling of 3000 vials, loading in the lyophilizer, and exposure to a portion of the nitrogen flush and then stoppering. Since lyophilizer sterilization and sterilization of the nitrogen system used to backfill require separate validation, media fills should primarily validate the filling, transportation and loading aseptic operations. 

         The question of the number of units needed for media fills when the capacity of the process is less than 3000 units is frequently asked, particularly for clinical products. Again, the purpose of the media fill is to assure that product can be aseptically processed without contamination under operating conditions. It would seem, therefore, that the maximum number of units of media filled be equivalent to the maximum batch size if it is less than 3000 units.

         After filling, dosage units are transported to the lyophilizer by metal trays. Usually, the bottom of the trays are removed after the dosage units are loaded into the lyophilizer. Thus, the dosage units lie directly on the lyophilizer shelf. There have been some situations in which manufacturers have loaded the dosage units on metal trays which were not removed. Unfortunately, at one manufacturer, the trays warped which caused a moisture problem in some dosage units in a batch. 

         In the transport of vials to the lyophilizer, since they are not sealed, there is concern for the potential for contamination. During inspections and in the review of new facilities, the failure to provide laminar flow coverage or a primary barrier for the transport and loading areas of a lyophilizer has been regarded as an objectionable condition. One manufacturer as a means of correction developed a laminar flow cart to transport the vials from the filling line to the lyophilizer. Other manufacturers building new facilities have located the filling line close to the lyophilizer and have provided a primary barrier extending from the filling line to the lyophilizer.

         In order to correct this type of problem, another manufacturer installed a vertical laminar flow hood between the filling line and lyophilizer. Initially, high velocities with inadequate return caused a contamination problem in a media fill. It was speculated that new air currents resulted in rebound contamination off the floor. Fortunately, media fills and smoke studies provided enough meaningful information that the problem could be corrected prior to the manufacture of product. Typically, the lyophilization process includes the stoppering of vials in the chamber.

 

         Another major concern with the filling operation is assurance of fill volumes. Obviously, a low fill would represent a subpotency in the vial. Unlike a powder or liquid fill, a low fill would not be readily apparent after lyophilization particularly for a biopharmaceutical drug product where the active ingredient may be only a milligram. Because of the clinical significance, sub-potency in a vial potentially can be a very serious situation. 

         For example, in the inspection of a lyophilization filling operation, it was noted that the firm was having a filling problem. The gate on the filling line was not coordinated with the filling syringes, and splashing and partial filling was occurring. It was also observed that some of the partially filled vials were loaded into the lyophilizer. This resulted in rejection of the batch.

         On occasion, it has been seen that production operators monitoring fill volumes record these fill volumes only after adjustments are made. Therefore, good practice and a good quality assurance program would include the frequent monitoring of the volume of fill, such as every 15 minutes. Good practice would also include provisions for the isolation of particular sections of filling operations when low or high fills are encountered. 

          There are some atypical filling operations which have not been discussed. For example, there have also been some situations in which lyophilization is performed on trays of solution rather than in vials. Based on the current technology available, it would seem that for a sterile product, it would be difficult to justify this procedure. 

          The dual chamber vial also presents additional requirements for aseptic manipulations. Media fills should include the filling of media in both chambers. Also, the diluent in these vials should contain a preservative. (Without a preservative, the filling of diluent would be analogous to the filling of media. In such cases, a 0% level of contamination would be expected.) 


 